Suggestions For Performing Infrared Inspections Of Motor Control Centers

The Motor Control Center

The MCC enclosure protects personnel from contact with present-day carrying systems, and it protects the segments from various environmental factors. It is important that the enclosure is mounted to guarantee accessibility therefore competent personnel (such as an experienced thermographer) is able to open up the board under load. You will discover many instructional classes and kinds of MCCs, but generally speaking, an MCC looks like a row of file cabinets with every single cabinet representing an MCC section. The drawers of the file box represent the plug in models which contain the motor control components. Three phase power is sent out within the MCC by bus bars, big alloy current carrying bars. The horizontal bus provides three-phase power distribution from the main energy supply. Vertical bus in each area is linked from it to unique MCCs. Bracing and isolation barriers are provided to defend against fault conditions. The plug in models of an MCC have power stabs on the back to permit it to be plugged into the vertical power bus bars of the construction.

Beginning Your MCC Infrared Inspection

Before opening the control panel or maybe door on a motor controller, prescan the enclosure to ensure a protected opening condition. If excessive heat is found on the surface of the door, extra attention ought to be taken when opening it. The escort or thermographer might want to note the state as unacceptable and not take a chance on opening it under load. Once the system is opened, start with both an infrared in addition to a visual inspection to assure no perilous circumstances exist. Be systematic while conducting the infrared inspection. Remember the system has to be under load to conduct the inspection. Work from left to right or follow the circuit through thoroughly, inspecting the pieces. Look for abnormal thermal patterns caused by high-resistance connections, overloads, or perhaps load imbalances. In three-phase systems this could be achieved by comparing phases. Adjust the level and span on the infrared system to improve the image. Proper adjustment is going to identify primary and secondary anomalies. The bus stabs as well as the connections to the primary are crucial inspection points that are frequently disregarded or misdiagnosed. The new link to the primary horizontal bus is generally located behind a cover or perhaps control panel that is not hinged. These are normally bolted connections and contains parallel feeders. The bus stab connections on the back of the plug-in devices are harder to check out. The thermographer doesn’t have one on one view of the connection, and also the initial indication of a problem can be seen on the new conductors feeding the breaker or fused disconnect. Don’t forget, even tiny temperature rises identified at this time might suggest severe issues.

Motor Starters as well as Motor Controllers

The goal of the motor starter is protecting the motor, personnel, and connected devices. Over ninety % of the motors used are AC induction motors, and also motor starters are used to get started in and stop them. A far more generic term would find this particular unit as a motor controller. A controller could consist of several options, like establishing, stopping, overcurrent protection, overload protection, reversing, and braking. The engine starter is selected to complement the voltage and also horsepower of the model. Other things used to decide on the starter include: motor speed, torque, full load current (FLC), service factor (SF), and also time rating (10 or 20 seconds).


Understanding the thermal patterns of this machines is critical to a successful inspection. Also correctly identifying the source of the anomaly can get recommendations more valuable.

Motors may be weakened or maybe their lifestyle significantly lowered if they perform continually at a current above total load current. Motors are supposed to deal with in rush or even locked rotor currents without much temperature increase, as long as there is a limited length and a small number of starts. Overcurrents as much as locked rotor current are often due to technical overloading of the engine. The National Electric Code (NEC) describes overcurrent protection due to this scenario as “motor going overcurrent (overload) protection.” This could be shortened to overload protection. Overcurrents induced by short circuits or perhaps ground faults are dramatically higher than those brought on by mechanical overloads or too much starts. The NEC describes the kind of overcurrent protection as “motor branch circuit short circuit and ground fault protection.” This might be shortened to overcurrent protection. The 4 frequent varieties of motor starters are: across-the-line, the reversing starter, the multispeed starter, and the reduced voltage starter. Motor starters are generally composed of the same types of components. These include a breaker or even fused disconnect, contactor and overloads. There may additionally be extra factors, including management circuitry as well as a transformer. Understanding the cold weather patterns of the equipment is crucial to a prosperous inspection. Also correctly determining the source of the anomaly can make recommendations more valuable.

Overcurrent Protection

Overcurrent protection is needed by NEC and a way to disconnect the motor and controller from line voltage. Fused disconnects or thermal magnetic circuit breakers are usually chosen for overcurrent protection also to provide a disconnect for the circuit. A circuit breaker is identified in NEMA requirements as a device made to be able to open and close a circuit by non automatic means and also to start the circuit automatically on a predetermined overcurrent without trauma to itself when adequately applied within its rating. If we look at a cutaway of any breaker, we are able to determine possible relationship problems. The line side and fill side lugs would be the most frequent source of abnormal heating, but a lot of breakers have a second set of bolted connections on the back of the breaker. Heat from this particular connection can be misdiagnosed as the key lug. Also, there are bodily contacts where current flow is interrupted by working out the component. These contacts experience arcing whenever the breaker is opened. An arc is a discharge of electric current jumping across an air gap between 2 contacts. Arcs are formed when the relationships of a circuit breaker are opened under a lot. Arcing under normal loading is quite small than an arc produced from a short circuit interruption. Arcing produces additional heat plus can cause damage to the communication surfaces. Damaged relationships can cause resistive heating. Thermal patterns from these poor connections show up as diffuse heating along the surface of the breaker. Furthermore, there are a number of sorts of breakers with internal coils used for circuit protection. These coils have heat connected with them and will seem to be an internal heating problem, when in fact, it is a typical condition.

Fused Disconnects

Fused disconnects are utilized to supply over-current protection for motor in the very same manner as a breaker. Rather than opening contacts, fuses fail opening the circuit. When overcurrent protection is supplied by fuses, a disconnect switch is needed for manual opening of the circuit. The disconnect switch and fuse block are one assembly. The blade and hinge connections on the switch are a normal tool of overheating. High resistance from overuse or underuse is usually the cause. Fuse clips are furthermore a weak connection point for some disconnect designs. A variety of types as well as manufacturers of fuses of the very same amperage may generate various thermal signatures. While different size or amperage fuses will in addition have a distinct cold weather pattern, fuse bodies may appear hotter than the majority of the circuit on account of conductor size.

Contactors

Starters are made from two building blocks, overload protection and also contactors. Contactors put a cap on the electrical current flow to the motor. Their purpose is usually to repeatedly set up and disrupt an electric power circuit. A contactor is able to stand by itself as a strength suppression device, or included in a starter. Contactors operate electromechanically and make use of a little control existing to open and close the circuit. The electromechanical components do the job, not the human hand, as is the circumstances with a knife blade switch or a manual controller. The sequence of operation of a contactor is as follows: first, a control current is used on the coil; next, current flow into the coil produces a magnetic field that magnetizes the E-frame allowing it to be an electromagnet; finally, the electromagnet draws the armature towards it, closing the contacts. A contactor incorporates a life expectancy. If the contactor contacts are frequently opened as well as closed, it is going to shorten the lifetime of the product. As single phase motor forward reverse wiring diagram pdf are exercised, an electric-powered arc is produced between the contacts. Heat is produced by arcs, which can harm the contacts. Contacts eventually become oxidized by way of a black deposit. This black deposit may perhaps actually improve the power relationship between the contacts by enhancing the seat, but burn marks, pitting, as well as corrosion point it’s time to replace the contacts. The second winter patterns are connected with contactors. The coil of the contactor is ordinarily the warmest part of the product. temperatures which are High may suggest a breakdown of the coil. Line side and stuff side lug connections might reveal high resistance heating from terrible connections. Heating from burned and pitted relationships might be thermally “visible” on the body of the contactor.

Overload Protection

The perfect motor overload protection is a product with current sensing functions similar to the heating curve of the motor. It will open up the motor circuit when total load current is maxed out. Oper